Design rendering of an aluminum-framed retractable fabric roof over a garden terrace
Retractable roof systems

Motorized PVC Retractable Roof Systems for Project Supply.

Open a terrace to the sky with a motorized PVC retractable roof. Single sets reach 7000 mm wide × 8500 mm projection (approx. 22.97 × 27.89 ft), with the support layout matched to the size.

Aluminum frame and folding PVC retractable roof system
Motorized folding PVC roof
01 / System overview

Coordinate a PVC Retractable Roof as One System.

We supply motorized PVC retractable roofs for distributors, contractors and project buyers. The aluminum frame, guided folding cover, tracks and drainage are configured around site dimensions, with single sets up to 7000 mm wide × 8500 mm projection (approx. 22.97 × 27.89 ft). Rails, posts and connection beams are matched to the size and confirmed on approved drawings.

  • Aluminum frame and fixed tracks
  • Folding PVC and polyester cover
  • Motorized track-guided roof movement
  • Crossbars support the folding fabric
  • Gutter and post drainage route
  • Parallel tracks and coordinated modules
  • Optional integrated LED strip lighting
  • Wireless multi-channel control options
  • Wall-supported and freestanding layouts
  • Compatible side screens and enclosures
02 / Outdoor comfort, made flexible

Four Decisions Behind a Coordinated Retractable Roof.

The roof arrangement links the folding cover, drive, track layout and support format. Confirm those choices against the site dimensions and installation drawing before the order is prepared.

Retractable PVC roof weather-management example showing roof fall, fabric support, water baffle and gutter outlet coordination
01 / Weather management

Plan the Roof Fall and Water Route Before Production.

The folding PVC cover, tensioning detail, crossbars, water baffle and gutter must work with the selected slope and installation height. Final rain and wind suitability depends on the complete configuration and site conditions rather than the fabric alone.

  • Water routed through the gutter and posts to the post base
  • Rubber water-stop strips along the sides of the rail / gutter assembly
  • Gutter outlet position coordinated on the drawing
PVC retractable roof project structure with a transparent enlarged synchronous belt and drive wheel detail
02 / Movement and control

Coordinate the Folding Cover and Motorized Drive.

A motor drives the transmission shaft and track-mounted sliding modules to extend or fold the PVC cover. The synchronous belt coordinates movement across parallel rails, while the final motor and control package is selected for the approved module arrangement.

  • Track-guided folding movement
  • Synchronous-belt drive and coordinated rails
  • Wireless control, lighting and module grouping
Wall-supported multi-track retractable fabric roof above a dining terrace
03 / Size and configuration

Choose Tracks and Modules Around the Roof Footprint.

We supply single-set configuration examples up to 7000 mm wide × 8500 mm projection (approx. 22.97 × 27.89 ft). Widths over 5000 mm (approx. 16.40 ft) require an intermediate rail and one additional rear center post. Projection-direction connection beams are required at these widths from 4000 mm projection (approx. 13.12 ft); width-direction beams are also required unless the rails mount to a wall. Narrower long-projection layouts can also need added rails and beams, as detailed in the specification table. Custom dimensions and all supports follow approved drawings.

  • Front height, rear height, width and projection required
  • Intermediate rail and extra rear center post where required
  • Door clearance and folded-fabric drop checked early
04 / Installation and supply

Match Roof Supports to the Existing Structure.

Wall-supported, freestanding, suspended, steel-frame and gable arrangements place different demands on brackets, columns, clearances and drainage. The component list and package identification should follow the selected installation format.

  • Concealed base with a double-layer connection
  • Side screens or enclosure options coordinated where required
  • Hardware and profile openings prepared for the selected support format
03 / Specifications

What sizes and specifications are available for PVC retractable roofs?

Single-set configuration examples up to 7000 mm width × 8500 mm projection (approx. 22.97 × 27.89 ft). Widths over 5000 mm (approx. 16.40 ft) require an intermediate rail and one additional rear center post; connection beams follow the width, projection and mounting arrangement on approved drawings. We use 6063 aluminum framing and 835 g/m² (approx. 24.63 oz/yd²) PVC/polyester fabric. Custom dimensions and the complete support layout are confirmed on approved drawings.

ItemStandard / AvailableMade to order
SizeSingle-set configuration examples up to 7000 mm width × 8500 mm projection (approx. 22.97 × 27.89 ft)Custom dimensions; required intermediate rail, rear center post and connection beams confirmed on approved drawings
Material6063 aluminum alloy
Rail section130 × 70.2 × 2.3 mm (approx. 5.12 × 2.76 × 0.09 in)
Post section143.9 × 101.9 × 2 mm (approx. 5.67 × 4.01 × 0.08 in)
Gutter section150 × 130.3 × 2.5 mm (approx. 5.91 × 5.13 × 0.10 in)
FabricPVC / polyester, 835 g/m² (approx. 24.63 oz/yd²)Fabric construction and color selected by order
End support bar80 × 65.2 × 1.4 mm (approx. 3.15 × 2.57 × 0.06 in)
Intermediate support bar65.2 × 39.5 × 1.4 mm (approx. 2.57 × 1.56 × 0.06 in)
Crossbar spacing450–500 mm (approx. 17.72–19.69 in)Arrangement matched to module
Finish and colorsPowder coating or anodizing; fabric in beige, white or grayFrame color approved by sample
OperationMotorized synchronous-belt drive with wireless controlCompatible multi-channel control package
DrainageGutter and posts route water to the post base; side water-stop stripsOutlet position coordinated with the site
MountingWall-supported or post-supported arrangementHeights, roof slope and module layout to the drawing
AccessoriesOptional 3000K LED strips and compatible side enclosuresScreens, louvered shutters or sliding doors/windows by configuration
PackingCartonsOptional wooden crates
Intermediate rail and rear center postRequired at widths 5500–7000 mm for all matrix projections 2000–8500 mm (approx. 18.04–22.97 ft; 6.56–27.89 ft); adding an intermediate rail requires one additional rear center postAlso required at width 5000 mm with projection ≥4500 mm; width 4500 mm with projection ≥7000 mm; width 4000 mm with projection ≥8000 mm (approx. 16.40 / 14.76 / 13.12 ft wide; 14.76 / 22.97 / 26.25 ft projection). Final layout to approved drawings
Projection-direction connection beamsRequired from these projection examples by width: 2000–2500 mm wide → 7000 mm projection; 3000 → 6500; 3500 → 5000; 4000–4500 → 4500; 5000–7000 → 4000 mm (approx. widths 6.56–8.20 / 9.84 / 11.48 / 13.12–14.76 / 16.40–22.97 ft; projections 22.97 / 21.33 / 16.40 / 14.76 / 13.12 ft)Required at and above the matrix thresholds; custom support layout confirmed on approved drawings
Width-direction connection beamsRequired at widths 5500–7000 mm for all matrix projections; width 5000 mm with projection ≥4500 mm; width 4500 mm with projection ≥5000 mm; width 4000 mm with projection ≥5500 mm (approx. widths 18.04–22.97 / 16.40 / 14.76 / 13.12 ft; projections 14.76 / 16.40 / 18.04 ft)Not required when the rails mount to a wall; confirm the mounting arrangement and support layout on approved drawings
04 / Installation overview

How is a PVC retractable roof installed?

Every order includes a detailed installation manual and drawings. Use this five-step overview to coordinate the selected system with your installer; protective packing and opening or module labels support site identification.

01Review the roof footprint

Check width, projection, front and rear heights and clear height.

02Confirm roof supports

Review the wall or post layout and interfaces on the approved drawing.

03Identify roof components

Match tracks, crossbars, fabric and hardware to the module labels.

04Coordinate drainage and controls

Follow the supplied drawings for roof fall, outlets, motor and selected lighting.

05Check roof operation

Review folding movement, drainage route and the selected controls with the installer.

Retractable roof buyer questions

What Buyers Usually Confirm Next.

What sizes are available for a PVC retractable roof?

Single-set configuration examples extend to 7000 mm width × 8500 mm projection (approx. 22.97 × 27.89 ft). Widths over 5000 mm (approx. 16.40 ft) require an intermediate rail and one additional rear center post. Connection beams depend on width, projection and wall mounting; narrower long-projection layouts can also need added supports. See the supporting-layout rows in the specification table. Custom dimensions and all required components are confirmed on approved drawings.

What should I send for a retractable roof quotation?

Send width, projection, front and rear heights, clear height, support conditions, quantity and destination. Include drawings or site photos and your lighting, control and side-screen requirements. We aim to reply within 24 hours.

Is a PVC retractable roof waterproof and wind resistant?

Our PVC retractable roof manages rain with a guided fabric cover, side water-stop strips, gutters and drainage through the posts. We match the roof slope, frame and anchoring to your site and exposure, with the water route planned together with the module layout for your terrace or outdoor seating area.

How is a PVC retractable roof different from a louvered pergola?

A PVC retractable roof folds a guided fabric cover along fixed tracks, while a louvered pergola rotates rigid roof blades. The folding fabric creates an open-sky effect when retracted, and our system combines aluminum framing, motorized operation and gutter/post drainage with optional lighting and compatible side enclosures for outdoor living areas.

How do I measure the width and projection of a retractable roof?

Measure width across the outer sides of the rails and projection horizontally from the wall bracket to the front post position. Allow for the 40–50 mm (approx. 1.57–1.97 in) track extension beyond the projection, and include front, rear and clear heights on the drawing so we can arrange the roof slope and supporting layout.

Can a retractable roof have lighting and side screens?

Yes, optional 3000K LED strips can be integrated with selected crossbars, and compatible side screens or enclosures can be added. Zip screens, louvered shutters and sliding doors or windows offer different ways to shape the space, with the lighting and compatible multi-channel controls coordinated as part of your selected roof configuration.

Can I choose where the retractable roof drains?

Yes, we coordinate the drainage outlet positions with your installation layout. The roof gutter carries water through the posts to the post base, and the discharge route can be planned around the terrace levels and surrounding drainage, with the selected outlet positions included alongside the frame and module arrangement on the drawing.

Ready to configure the roof system?

Share the Opening, Projection, Heights and Installation Format.

Send the site dimensions, quantity, destination and available drawings or photos. The team can organize the relevant track, frame, fabric, motor and drainage discussion.

Target first response: within 24 hours. For urgent orders, contact us via WhatsApp or call +86 137 0291 0241.
Home
Products
Factory
Contact